<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Monitor Engineering &#187; control valves</title>
	<atom:link href="http://www.monitorspray.co.za/tag/control-valves/feed" rel="self" type="application/rss+xml" />
	<link>http://www.monitorspray.co.za</link>
	<description>Spray Nozzle and Pump Solutions</description>
	<lastBuildDate>Mon, 11 Oct 2010 19:52:24 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=2.8.3</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>TeeValve® Control Valves</title>
		<link>http://www.monitorspray.co.za/teevalve%c2%ae-control-valves.php</link>
		<comments>http://www.monitorspray.co.za/teevalve%c2%ae-control-valves.php#comments</comments>
		<pubDate>Wed, 02 Sep 2009 12:22:58 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[control valves]]></category>
		<category><![CDATA[valves]]></category>

		<guid isPermaLink="false">http://www.monitorspray.co.za/?p=986</guid>
		<description><![CDATA[
Model AA17
For selective control of three section boom sprayers at pressures up to 300 psi (20 bar).
Features

 Use to open any of three boom section lines in any desired combination.
Raise lever to open, lower lever to close the valve without changing the indexed position.
Aluminum construction with stainless steel and plastic internal parts for maximum corrosion [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-1404" style="margin-left: 0px; margin-right: 15px;" title="Control Valve" src="http://www.monitorspray.co.za/wordpress/wp-content/uploads/Control-Valve.jpg" alt="Control Valve" width="400" height="219" /><br />
<strong>Model AA17</strong></p>
<p>For selective control of three section boom sprayers at pressures up to 300 psi (20 bar).</p>
<p><strong>Features</strong></p>
<ul>
<li> Use to open any of three boom section lines in any desired combination.</li>
<li>Raise lever to open, lower lever to close the valve without changing the indexed position.</li>
<li>Aluminum construction with stainless steel and plastic internal parts for maximum corrosion resistance.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.monitorspray.co.za/teevalve%c2%ae-control-valves.php/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AA144A-1-3 DirectoValve® Control Valves</title>
		<link>http://www.monitorspray.co.za/aa144a-1-3-directovalve%c2%ae-control-valves.php</link>
		<comments>http://www.monitorspray.co.za/aa144a-1-3-directovalve%c2%ae-control-valves.php#comments</comments>
		<pubDate>Wed, 02 Sep 2009 11:34:26 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[control valves]]></category>
		<category><![CDATA[manifolds]]></category>
		<category><![CDATA[valves]]></category>

		<guid isPermaLink="false">http://www.monitorspray.co.za/?p=951</guid>
		<description><![CDATA[
The three-way solenoid-operated DirectoValve control valve bypasses boom flow to maintain constant spraying pressure when one or more boom sections are shut off. To maintain pressure with a 23520 throttling valve, outlet 2 must be throttled to match the total capacity of the nozzles on that boom section.
Features

For pressures up to 65 psi (4.5 bar).
8 [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-1388" style="margin-left: 0px; margin-right: 15px;" title="144A-1-3" src="http://www.monitorspray.co.za/wordpress/wp-content/uploads/144A-1-3.jpg" alt="144A-1-3" width="148" height="300" /><br />
The three-way solenoid-operated DirectoValve control valve bypasses boom flow to maintain constant spraying pressure when one or more boom sections are shut off. To maintain pressure with a 23520 throttling valve, outlet 2 must be throttled to match the total capacity of the nozzles on that boom section.<br />
<strong>Features</strong></p>
<ul>
<li>For pressures up to 65 psi (4.5 bar).</li>
<li>8 gpm (30 l/min) with a 5 psi (0.34 bar) pressure drop.</li>
<li>2.5 amp current draw.</li>
<li>Encapsulated 12 VDC coil can be easily changed without removing valve from line.</li>
<li>Polypropylene body for chemical resistance.</li>
<li>Internal metal parts are stainless steel.</li>
<li>Chemical resistant EPDM diaphragms and seat washers.</li>
</ul>
<p><strong>Note:</strong> 23520 throttling valve not included.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.monitorspray.co.za/aa144a-1-3-directovalve%c2%ae-control-valves.php/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AA144P-1-3 DirectoValve® Control Valves</title>
		<link>http://www.monitorspray.co.za/aa144p-1-3-directovalve%c2%ae-control-valves.php</link>
		<comments>http://www.monitorspray.co.za/aa144p-1-3-directovalve%c2%ae-control-valves.php#comments</comments>
		<pubDate>Wed, 02 Sep 2009 11:30:43 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[control valves]]></category>
		<category><![CDATA[manifolds]]></category>
		<category><![CDATA[valves]]></category>

		<guid isPermaLink="false">http://www.monitorspray.co.za/?p=949</guid>
		<description><![CDATA[
The 144P-1-3 three-way solenoid-operated DirectoValve control valve was specifically designed to provide bypass control in spraying applications. When used with part number 23520-PP throttling valve or a 4916 metering orifice place in the bypass line, it can provide for a constant pressure spray system.
Features

For pressures up to 65 psi (4.5 bar).
8 gpm (30 l/min) with [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-1384" style="margin-left: 0px; margin-right: 15px;" title="AA144P-1-3" src="http://www.monitorspray.co.za/wordpress/wp-content/uploads/AA144P-1-3.jpg" alt="AA144P-1-3" width="127" height="300" /><br />
The 144P-1-3 three-way solenoid-operated DirectoValve control valve was specifically designed to provide bypass control in spraying applications. When used with part number 23520-PP throttling valve or a 4916 metering orifice place in the bypass line, it can provide for a constant pressure spray system.<br />
<strong>Features</strong></p>
<ul>
<li>For pressures up to 65 psi (4.5 bar).</li>
<li>8 gpm (30 l/min) with a 5 psi (0.34 bar) pressure drop.</li>
<li>Fabric reinforced Viton® diaphragms.</li>
<li>Nylon encapsulated 12 VDC coil with 1/4&#8243; QuickConnect terminals.</li>
<li>Power requirement 2.5 amp.</li>
<li>Glass filled polypropylene (black) valve body.</li>
<li>Internal metal parts are stainless steel.</li>
<li>No stroke adjustment needed.</li>
<li>Corrosion resistant, 430SS solenoid grade armature and armature stop.</li>
</ul>
<p><strong>Note:</strong> 23520 throttling valve not included..</p>
]]></content:encoded>
			<wfw:commentRss>http://www.monitorspray.co.za/aa144p-1-3-directovalve%c2%ae-control-valves.php/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AA145H DirectoValve® Control Valves</title>
		<link>http://www.monitorspray.co.za/aa145h-directovalve%c2%ae-control-valves.php</link>
		<comments>http://www.monitorspray.co.za/aa145h-directovalve%c2%ae-control-valves.php#comments</comments>
		<pubDate>Wed, 02 Sep 2009 11:29:22 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[control valves]]></category>
		<category><![CDATA[manifolds]]></category>
		<category><![CDATA[valves]]></category>

		<guid isPermaLink="false">http://www.monitorspray.co.za/?p=946</guid>
		<description><![CDATA[
Features

Direct acting; large internal flow chamber without pilot hole reduces chance of clogging.
Stainless steel wetted parts provide additional corrosion resistance.
Operates on 12 VDC system.
Maximum pressure of 100 psi (7 bar).
Encapsulated solenoid coil can be changed without removing valve from system.
EPDM diaphragms and seat washers, Viton® optional.
Continuous flow through bypass connection, with flow to spray line [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-1382" style="margin-left: 0px; margin-right: 15px;" title="AA145H" src="http://www.monitorspray.co.za/wordpress/wp-content/uploads/AA145H.jpg" alt="AA145H" width="162" height="300" /><br />
<strong>Features</strong></p>
<ul>
<li>Direct acting; large internal flow chamber without pilot hole reduces chance of clogging.</li>
<li>Stainless steel wetted parts provide additional corrosion resistance.</li>
<li>Operates on 12 VDC system.</li>
<li>Maximum pressure of 100 psi (7 bar).</li>
<li>Encapsulated solenoid coil can be changed without removing valve from system.</li>
<li>EPDM diaphragms and seat washers, Viton® optional.</li>
<li>Continuous flow through bypass connection, with flow to spray line controlled by valve &#8220;on-off&#8221; action.</li>
<li>15 gpm (56.7 l/min) with 5 psi (0.34 bar) pressure drop.</li>
<li>Can be ganged with other 145H DirectoValve control valves.</li>
<li>2.9 amp current draw.</li>
<li>Fiberglass reinforced nylon body.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.monitorspray.co.za/aa145h-directovalve%c2%ae-control-valves.php/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AA144A DirectoValve® Control Valves</title>
		<link>http://www.monitorspray.co.za/aa144a-directovalve%c2%ae-control-valves.php</link>
		<comments>http://www.monitorspray.co.za/aa144a-directovalve%c2%ae-control-valves.php#comments</comments>
		<pubDate>Wed, 02 Sep 2009 11:27:32 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[control valves]]></category>
		<category><![CDATA[manifolds]]></category>
		<category><![CDATA[valves]]></category>

		<guid isPermaLink="false">http://www.monitorspray.co.za/?p=943</guid>
		<description><![CDATA[
Features

Direct acting; large internal flow chamber without pilot hole reduces chance of clogging.
Stainless steel wetted parts provide additional corrosion resistance.
Operates on 12 VDC system.
Maximum pressure of 100 psi (7 bar).
Encapsulated solenoid coil can be changed without removing valve from system.
EPDM diaphragms and seat washers, Viton® optional.
Continuous flow through bypass connection, with flow to spray line [...]]]></description>
			<content:encoded><![CDATA[<p><img class="alignright size-full wp-image-1380" style="margin-left: 0px; margin-right: 15px;" title="AA144A" src="http://www.monitorspray.co.za/wordpress/wp-content/uploads/AA144A.jpg" alt="AA144A" width="312" height="300" /><br />
<strong>Features</strong></p>
<ul>
<li>Direct acting; large internal flow chamber without pilot hole reduces chance of clogging.</li>
<li>Stainless steel wetted parts provide additional corrosion resistance.</li>
<li>Operates on 12 VDC system.</li>
<li>Maximum pressure of 100 psi (7 bar).</li>
<li>Encapsulated solenoid coil can be changed without removing valve from system.</li>
<li>EPDM diaphragms and seat washers, Viton® optional.</li>
<li>Continuous flow through bypass connection, with flow to spray line controlled by valve &#8220;on-off&#8221; action.</li>
<li>10 gpm (37.9 l/min) with 5 psi (0.34 bar) pressure drop.</li>
<li>Can be ganged with other 144A DirectoValve control valves.</li>
<li>2.5 amp current draw.</li>
<li>Polypropylene body for chemical resistance.</li>
<li>Fabric reinforced diaphragms.</li>
<li>Also available as 2- or 3-unit assembly.</li>
</ul>
]]></content:encoded>
			<wfw:commentRss>http://www.monitorspray.co.za/aa144a-directovalve%c2%ae-control-valves.php/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>AA144P DirectoValve® Control Valves</title>
		<link>http://www.monitorspray.co.za/aa144p-directovalve%c2%ae-control-valves.php</link>
		<comments>http://www.monitorspray.co.za/aa144p-directovalve%c2%ae-control-valves.php#comments</comments>
		<pubDate>Wed, 02 Sep 2009 11:20:54 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[control valves]]></category>
		<category><![CDATA[manifolds]]></category>
		<category><![CDATA[valves]]></category>

		<guid isPermaLink="false">http://www.monitorspray.co.za/?p=941</guid>
		<description><![CDATA[Features

Direct acting; large internal flow chamber without pilot hole reduces chance of clogging.
 Stainless steel wetted parts provide additional corrosion resistance.
Operates on 12 VDC system.
Maximum pressure of 100 psi (7 bar).
Encapsulated solenoid coil can be changed without removing valve from system.
EPDM diaphragms and seat washers, Viton® optional.
Continuous flow through bypass connection, with flow to spray [...]]]></description>
			<content:encoded><![CDATA[<p><strong><img class="alignright size-full wp-image-1374" title="AA144P" src="http://www.monitorspray.co.za/wordpress/wp-content/uploads/AA144P1.jpg" alt="AA144P" width="140" height="300" />Features</strong></p>
<ul>
<li>Direct acting; large internal flow chamber without pilot hole reduces chance of clogging.</li>
<li> Stainless steel wetted parts provide additional corrosion resistance.</li>
<li>Operates on 12 VDC system.</li>
<li>Maximum pressure of 100 psi (7 bar).</li>
<li>Encapsulated solenoid coil can be changed without removing valve from system.</li>
<li>EPDM diaphragms and seat washers, Viton® optional.</li>
<li>Continuous flow through bypass connection, with flow to spray line controlled by valve &#8220;on-off&#8221; action.</li>
<li>10 gpm (37.9 l/min) with 5 psi (0.34 bar) pressure drop.</li>
<li>2.5 amp current draw.</li>
<li>Polypropylene body for chemical resistance.</li>
<li>Fabric reinforced Viton diaphragms and seat washers.</li>
<li>No stroke adjustment required.</li>
<li>Corrosion resistant, 430SS solenoid grade armature and armature stop.</li>
<li>Encapsulated coil and magnetic circuit.</li>
</ul>